A 9,170 m² green roof that stops leaking — without stopping the plant
Investigation of leaks in the green roof of Ecoparc 3 in Sant Adrià de Besòs, a metropolitan waste treatment plant, and design of the emergency works and permanent solution, for the Barcelona Metropolitan Area.

The challenge
Since 2024 water had been getting into the pre-treatment hall, electrical rooms, weighbridge and offices, and in December 2025 heavy rain damaged the control room. The PVC membrane was twenty years old, the laps had come apart and the profiled steel deck underneath was corroding under trapped water. All above a plant that treats waste every day of the year.
The solution
We identified five leakage mechanisms and ranked them by strength of evidence. We compared four options and five waterproofing systems through a multi-criteria analysis. The preferred option strips the roof back to the deck, repairs it, adds rock wool insulation and a mechanically fixed, root-resistant TPO membrane welded without a flame, installs 16 new outlets and 6 overflows, and reinstates the green roof and the 1,738 solar panels. Works run in three phases, with each sector made watertight before the next is opened.
The outcome
A green roof that stays watertight for at least fifteen years, keeps its solar array and weighs less than before: the new build-up takes about 32 kg/m² off the structure.
- Project
- Green roof renewal at Ecoparc 3
- Client
- Barcelona Metropolitan Area (AMB)
- Location
- Sant Adrià de Besòs (Barcelona)
- Year
- 2026
- Service
- Diagnosis, emergency works and design
- Sector
- Industrial
- Key technical aspects
- Defect diagnosisGreen roofsWaterproofingLive plant
What you don’t see